TRACERCO Diagnostics™ Tower Scan
Tracerco Asia was invited to carry out the
TRACERCO Diagnostics™ Tower scan technique to inspect
the condensate tower on a major operator’s plant in
Malaysia. The objective was to investigate the flooding
condition in the tower that was affecting the column parameters
and leading to discolouration and contamination of the condensate
naphtha stream.
The condensate tower was scanned in three
sections. The top section (Trays 1-9) was scanned using
scan lines along two chords at an orientation 90° -
270° (Scans T1 and T2). These passed through the active
areas of the trays, avoiding the side and centre downcomers.
The middle section (Trays 10 - 20) was scanned along the
0° -180° diameter, avoiding the side downcomer (Scan
C). The bottom section (Trays 21 – 30) was scanned
along two chords at the same orientations as for the scans
of the top section (Scans B1 and B2).
From Tray 21 down to Tray 25, the column was
completely flooded: although no flooding was observed below
Tray 25. This suggested that there was probably a restriction
in the Tray 25 downcomer. However, an alternative possibility
is that the flooding was a result of restrictions in the
hole-sizes on the active tray areas, caused by the lay down
of deposits.
On the North side of the tower, the tray
appeared to be operating satisfactorily, while on the South
side the profile of Tray 28 was irregular. It appeared to
be holding very little liquid, which indicated that this
side of the tray was dry, or partly damaged.
Trays 29 and 30 looked normal with clearly defined vapour
spaces and liquid levels. The liquid level on the North
side of the tower (200mm) appeared to be greater than that
observed on the South side (100mm), The condensate tower
was experiencing severe flooding conditions at the time
at which the scans were performed. The flooding extended
from Tray 25 up to the top tangent line. In the first scan,
Trays 1-4 appeared to be in position and functioning satisfactorily.
Tracerco Asia’s engineers’ recommendation
detailed in their preliminary report that a scan should
be done at a lower rate, or after the column had been flushed
and cleaned, to check the condition of the trays. The column
was then opened and cleaned and has been brought back on
line and is operating under normal conditions. Tracerco
Asia’s techniques were able to investigate and clarify
the flooding conditions within the tower, minimizing shutdown
time and helping the plant to effect speedy repairs and
a rapid return to full production of high quality product.