| Case Studies
TRACERCO Diagnostics™ MUI
An
increasing problem on vessels and pipelines within chemical
and refinery units is the “invisible menace”,
more commonly known as “corrosion under insulation”.
When this occurs unseen erosion of the pipe or vessel
wall takes place ultimately leading to either an operational
stoppage or at worse a catastrophic failure of the unit.
The TRACERCO Diagnostics™ MUI technology
offers an inspection tool to examine the water content of
the insulation. Although this does not directly examine
the condition of the metal wall it gives an accurate indication
as to the “wetness” of the insulation indicating
where the conditions for corrosion to occur are most prevalent.
The benefit of doing such a survey is that it gives the
client an early warning of an impending problem.
The unit is self-contained and allows for instantaneous
interpretation of the results to be made. The unit in operation
is shown below.
An
example of the successful use of the technology is on a
gas transportation line in Europe. This line is over 16km
long and suffered a catastrophic failure around 5 years
ago. On inspection the client found that this was due to
corrosion from the outside of the line and that the insulation
in this area was extremely wet. This obviously raised major
concerns as to the condition of the remainder of the line.
The TRACERCO Diagnostics™ MUI technology
was used to conduct a detailed examination of the line.
This initial survey showed significant areas of wet insulation,
which on removal showed that major “corrosion under
insulation” had taken place.
Large sections of the line were replaced and re- insulated
and since then an annual inspection has taken place. The
line has improved but even the latest survey showed one
area of concern.
If you feel your unit could be suffering from this “invisible
menace” then please feel free to contact
us.