| Case Studies
TRACERCO Diagnostics - Tower Scan
Maldistribution
was suspected in a packed bed of a Main Fractionator, on
a major European FCC unit. A TRACERCO Diagnostics
Tower scan was used to investigate the transfer/parting
box arrangement immediately above the bed. In addition,
a TRACERCO Diagnostics Tomography scan was performed
towards the top of the bed to supplement the traditional
tower scan, in an attempt to locate any areas of maldistribution
within the bed. The results of the tower scans carried out
are below - click on the image below for a larger view (the
transfer and parting box sections extending down to the
top part of the bed). These showed an increased liquid level
on the East side of the transfer box, with the density in
the East side of the bed around 10% higher than on the West
side.

A full TRACERCO Diagnostics Tomography scan was undertaken
on the bed around the top elevation. This involved 18 source
locations around the tower and detectors at 10 positions
for each source location. By knowing the source and detector
separation at each point of measurement a density can be
calculated at each intercept position by the use of simultaneous
equations.

The above is a 3D representation of one set of scans that
were performed - click on the image for a larger view.
The results correlated with the findings of conventional
TRACERCO Diagnostics Tower scan, in that a region
of lower density was detected on the West side of the bed
whilst there was a region of higher density on the East
side.
The above work, part of an on-going development programme
with some key customers, will give our clients much greater
detail regarding overall bed densities and will be offered
alongside the TRACERCO Diagnostics Distribution study
to provide a comprehensive survey of bed performance.