| Case Studies
TRACERCO Diagnostics™ Leak Study
Source of Water in Product Stream Identified
Process engineers were baffled by a dramatic increase in
the water concentration in their ethylene glycol product
stream. They sought the help of Tracerco to pinpoint the
source of the problem. In the design of this plant, the
pre-concentrator overheads, consisting of 170 psi steam,
were used to heat the reboiler of the concentrator, while
the bottoms from the preconcentrator was the concentrator
feed. The question was, did the excess water get carried
over with the feed , or was there a leak in the concentrator
reboiler?
Tracerco used their TRACERCO Diagnostics™
Leak Study technique to test the concentrator reboiler using
a radioisotope tracer. A small quantity of tracer was injected
into the overhead stream from the pre-concentrator.

As there wasn’t a sample point available on the reboiler
return to the concentrator, samples were taken off the column
bottoms and overheads. The samples were analysed for tracer
using liquid scintillation counting. A 7% leak in the overheads
and a 5% leak in the bottoms was indicated. This result
related well with the excess water showing up the product,
thus eliminating alternative causes. The reboiler was taken
off-line, repaired, and the plant was brought back on stream
making good quality product..
<< back
|