| Case Studies
TRACERCO Diagnostics™ Flow Study
Accurate Knowledge of Flow Essential to Energy Audit
Carrying out energy audits in a plant always highlights
problems, and it is on these occasions that accurate knowledge
of flowrates is essential. In this particular ammonia plant,
it was necessary to determine the flow in some unmeasured
streams as well as verify some existing flow meters. The
majority of flows that required measuring were steam and
airflow to various turbines and natural gas flow to various
furnaces. Tracerco was called in to use its TRACERCO
Diagnostics™ Flow Study technique to assist in
this energy audit.

Suitable gaseous and liquid radioisotope tracers were used
dependant upon the fluid under investigation. Velocities
were measured over the range 40-100 feet per second, with
accuracies varying from 98 to 99.5% depending upon the combination
of line length, pipe diameter and flowrate. These results
showed that the natural gas meter was indicating greater
than actual flow. When this correction was made, the fuel
gas usage was in line with forecast, and it turned out that
the plant had been overcharged for their natural gas for
a lengthy period of time. A good energy balance on the steam
system was also obtained for the first time, since flowmeters
were verified and previously unmeasured flowrates were not
known.
<< back
|