TRACERCO™ Density Gauge

The TRACERCO™ Density Gauge is a non-intrusive, non-wetted field instrument which utilizes advanced nucleonic measurement technology.

The TRACERCO™ Density Gauge utilizes advanced HART™ technology, which means there is;

  • A HART™ Digital Interface allowing direct communicators via the customer’s DCS system
  • A full HART™ protocol allowing asset management

Incorporation of HART™ technology in the field mounted detector allows communication via the customer’s DCS and eliminates the need for safe-area mounted control units.

The TRACERCO™ Density Gauge has a number of key features that differentiate it from the other industrial level gauges:

  • It provides real-time in line or in vessel measurements
  • It has no moving or wetted parts, leading to reduced maintenance and high reliability
  • The instrument detector is externally mounted, allowing it to cope with the harshest process conditions, fluids or solids
  • Flameproof enclosure certified EEx d IIC T5. Suitable for Zone 1 operation
  • Automatic compensation for source decay
  • External automatic compensation for changes in vessel operating pressure
  • Linear, table and logarithmic linearisation options for level correction
  • Extensive self-checking and diagnostic facilities
Specification  
Level/Density/Concentration Measurement HART™ compatible 4-20mA Output. External HART™ input for Pressure/Temperature correction.
External 4-20mA correction signal can be achieved when combined with a PRI 159.
0.5 second update interval of level/density/concentration measurement - constant output.
PRI 160 safe area mounted HART™ interface.
PRI 116c Field mounted measurement instrument.
EMC Both units comply with directive 89/336/EEC
Configuration HART™ Transmitter
Electrical Power Requirements 10-34V DC 2.5VA Power supply required for PRI 160. The PRI 160 supplies power
to the PRI 116c field mounted instrument.

PRI116C (Sensor instrument)
 
Sealing Sealing to IP66
Electrical Safety
Flameproof enclosure certified EEx d IIC T5 (Tamb= -20°C to +60°C)
Operating Temperature Range
-20°C to +60°C
Detector cable 5 core screened cable is required for connection between the PRI 160 and the field mounted PRI 116c unit
The PRI 116c is supplied with a pre-assembled flameproof gland and 4m flying lead as standard.
A flameproof junction box with appropriate glands is required to connect the PRI 116c-ATX to the PRI 160.

PRI160 (Modbus to HART converter)
 
Operating Temperature range
0°C to +70°C
Electrical Safety
Safe Area mounting only (DIN rail fitting)
Indicators
LED indicators provide instant recognition of power and connection to the PRI 116c-ATX.
Electrical 2 wire passive 4-20mA/HART™ interface to DCS.

HART™ is used under licence from HART Communications Foundation.