TRACERCO™ Density Gauge
The TRACERCO™ Density Gauge is a non-intrusive,
non-wetted field instrument which utilizes advanced nucleonic
measurement technology.
The TRACERCO™ Density Gauge utilizes advanced
HART™ technology, which means there is;
- A HART™ Digital Interface allowing direct
communicators via the customer’s DCS system
- A full HART™ protocol allowing asset management
Incorporation of HART™ technology in the field
mounted detector allows communication via the customer’s
DCS and eliminates the need for safe-area mounted control
units.
The TRACERCO™ Density Gauge has a number of
key features that differentiate it from the other industrial
level gauges:
- It provides real-time in line or in vessel measurements
- It has no moving or wetted parts, leading to reduced
maintenance and high reliability
- The instrument detector is externally mounted, allowing
it to cope with the harshest process conditions, fluids
or solids
- Flameproof enclosure certified EEx d IIC T5. Suitable
for Zone 1 operation
- Automatic compensation for source decay
- External automatic compensation for changes in vessel
operating pressure
- Linear, table and logarithmic linearisation options
for level correction
- Extensive self-checking and diagnostic facilities
| Specification |
|
| Level/Density/Concentration Measurement |
HART™ compatible 4-20mA Output. External
HART™ input for Pressure/Temperature correction.
External 4-20mA correction signal can be achieved when
combined with a PRI 159.
0.5 second update interval of level/density/concentration
measurement - constant output.
PRI 160 safe area mounted HART™ interface.
PRI 116c Field mounted measurement instrument. |
| EMC |
Both units comply with directive 89/336/EEC |
| Configuration |
HART™ Transmitter |
| Electrical Power Requirements |
10-34V DC 2.5VA Power supply required for PRI 160.
The PRI 160 supplies power
to the PRI 116c field mounted instrument. |
|
PRI116C (Sensor instrument)
|
|
| Sealing |
Sealing to IP66 |
Electrical Safety |
Flameproof enclosure certified EEx d IIC T5 (Tamb=
-20°C to +60°C) |
Operating Temperature Range |
-20°C to +60°C |
| Detector cable |
5 core screened cable is required for connection between
the PRI 160 and the field mounted PRI 116c unit
The PRI 116c is supplied with a pre-assembled flameproof
gland and 4m flying lead as standard.
A flameproof junction box with appropriate glands is
required to connect the PRI 116c-ATX to the PRI 160. |
|
PRI160 (Modbus to HART converter)
|
|
Operating Temperature range |
0°C to +70°C |
Electrical Safety |
Safe Area mounting only (DIN rail fitting) |
Indicators |
LED indicators provide instant recognition of power
and connection to the PRI 116c-ATX. |
| Electrical |
2 wire passive 4-20mA/HART™ interface
to DCS. |
|
HART™ is used under licence from HART Communications
Foundation.
 |
Brochure
A PDF version of the TRACERCO Density Gauge is
available, to download it click
here |
|